25-100 kVA Three Phase, On-Line Double Conversion, Uninterruptable Power System

Staco E2

25-100 kVA
Three Phase, On-Line Double Conversion, Uninterruptible Power Supply

In the event of an AC power failure, the Staco E2 UPS will automatically transfer to battery power and continue to provide power without any interruption for the full amount of time you select. When power returns, the Staco E2 UPS will automatically recharge the batteries for the next unexpected power outage or disturbance.

 


  • Output Unity Power Factor
  • Up to 95.3% Efficient
    • Lower energy costs and carbon footprint
    • Hot Standby Economy Mode available
  • Compact & Reliable
    • 208VAC or 480VAC models allows for smaller footprint
    • Cooler operation extends internal component life
  • AC Input Performance
    • High input power factor of 0.99
    • Low input current distortion of < 1% (THDi) @ full load
    • Soft Start Power walk-in function that ensures progressive rectifier start-up
  • Data Centers
  • Computer Networks
  • Industrial Process Manufacturing
  • Hospitals, Medical
  • Education, Research
  • Laboratories, Bio-tech
  • Pharmaceuticals
  • Critical Power Management Requirements

Product Selector | Firstline PLT

Click Below to Remove Existing Filters

VlZjeFIwMUhVa2hXYm14c1ZUQktWRnBHWXpGTlIwWllUVmQ0U2xJd1dYZFRWVkpHWkRBeFJGWlhaRlZTZW14dlYydE9RbUl5UmxoT1ZFSmhWMFZ3TVZkV1pETmpRVDA5: 8

30

8

Load kVA: 30
Input Voltage: 208Y/120
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 52 x 23.20 x 33
Weight (lbs.): 1125
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 208Y/120
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 52 x 23.20 x 33
Weight (lbs.): 1125
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 208Y/120
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 52 x 23.20 x 33
Weight (lbs.): 1125
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 208Y/120
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 72.4 x 23.1 x 34.5
Weight (lbs.): 1230
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 208Y/120
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 72.4 x 23.1 x 34.5
Weight (lbs.): 1240
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 208
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 72.4 x 23.1 x 34.5
Weight (lbs.): 1569
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 480
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 72.4 x 23.1 x 34.5
Weight (lbs.): 1573
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 480
Output Voltage: 480Y/277
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 72.4 x 23.1 x 34.5
Weight (lbs.): 1745
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 480Y/277
Output Voltage: 208Y/120
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 72.4 x 23.1 x 34.5
Weight (lbs.): 1493
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 30
Input Voltage: 480Y/277
Output Voltage: 480Y/277
Internal Maintenance Bypass: Yes
Internal Batteries: HR1290W
Dimensions (H" x W" x D"): 72.4 x 23.1 x 34.5
Weight (lbs.): 1745
Battery Runtime @ 100% Load (Internal): 8

Choose Your Location

Find a distributor in your area.

map

© 2022 Staco Energy Products Co. All Rights Reserved