Staco VP

6  & 10kVA (Rack / Tower Universal Mount)
Single Phase, On-Line Double Conversion, Uninterruptible Power Supply

The Staco VP hardwired series of UPS is highly configurable depending on load and application requirements. The UPS supports multiple voltages on the output, providing ultimate site flexibility.

When rack space is at a premium, even for the most power-dense loaded rack the UPS requires just 6U to fully protect a 42U loaded rack. For more industrial environments, the tower UPS is compact and requires minimal floor space.

A matching isolation transformer may be added to the standard UPS configuration for maximum site safety and reliability. The units may also be operated at full functionality without the battery, when power protection requirements call for a true Frequency Converter or Power Conditioner.

 


  • Voltage and Frequency Independent (VFI) Technology
  • Multiple output voltage configurations
  • Zero transfer time to battery
  • Galvanic isolation models
  • Modular configurable in standard rack
  • Frequency Converter and Power Conditioner options
  • Intelligent battery management
  • Integrated automatic bypass
  • Parallel up to 4 cabinets for power or redundancy
  • Extended runtime
  • Three year product warranty, 1 year battery warranty
  • Edge Devices
  • Mid-sized Networks
  • Telecom
  • Medical Equipment
  • Process Control
  • Any Mission Critical Application

*For more detailed application information, please refer to the following document: Single Phase UPS Application Notes: 6-30kVA

Load kVA / kW:
Input Voltage: 120
Output Voltage:
Input Cord: 2' Hardwired input cord
Output Connection: (7) NEMA 5-15/20R, 20A output receptacles
Dimensions W x H x D (inches): 17.38 x 8.72 x 8.42 (5U)
Weight (lbs): 20
Load kVA / kW:
Input Voltage: 120
Output Voltage:
Input Cord: 2' Hardwired input cord
Output Connection: (4) NEMA 5-15/20R, 20A & (2) L5-30R, 30A output receptacles
Dimensions W x H x D (inches): 17.38 x 8.72 x 8.42 (5U)
Weight (lbs): 20
Load kVA / kW:
Input Voltage: 120, 208, or 240
Output Voltage:
Input Cord: 2' Hardwired input cord
Output Connection: (4) NEMA 5-15/20R, 20A & (2) L6-30R, 30A output receptacles
Dimensions W x H x D (inches): 17.38 x 8.72 x 8.42 (5U)
Weight (lbs): 20
Load kVA / kW:
Input Voltage: 120, 208, or 240
Output Voltage:
Input Cord: 2' Hardwired input cord
Output Connection: (4) NEMA 5-15/20R, 20A, (1) L6-20R, 20A, & (2) L6-30R, 30A output receptacles
Dimensions W x H x D (inches): 17.38 x 8.72 x 8.42 (5U)
Weight (lbs): 20
Load kVA / kW:
Input Voltage: 120, 208, or 240
Output Voltage:
Input Cord: 2' Hardwired input cord
Output Connection: (4) NEMA 5-15/20R, 20A, (2) L6-20R, 20A, & (1) L6-30R, 30A output receptacles
Dimensions W x H x D (inches): 17.38 x 8.72 x 8.42 (5U)
Weight (lbs): 20
Load kVA / kW:
Input Voltage: 208 or 240
Output Voltage:
Input Cord: 2' Hardwired input cord
Output Connection: (3) NEMA L6-30R, 30A output receptacles
Dimensions W x H x D (inches): 17.38 x 8.72 x 8.42 (5U)
Weight (lbs): 20
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 26.64 (9U)
Weight (lbs): 323
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 26.64 (9U)
Weight (lbs): 323
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 26.64 (9U)
Weight (lbs): 323
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 26.64 (9U)
Weight (lbs): 323
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 26.64 (6U)
Weight (lbs): 175
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 26.64 (6U)
Weight (lbs): 175
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 26.64 (6U)
Weight (lbs): 175
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 26.64 (6U)
Weight (lbs): 175
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 258
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 258
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 258
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 258
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 179
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 179
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 179
Load kVA / kW: 6kVA / 5.4kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 179
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 30.77 (9U)
Weight (lbs): 380
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 30.77 (9U)
Weight (lbs): 380
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 30.77 (9U)
Weight (lbs): 380
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 15.45 x 30.77 (9U)
Weight (lbs): 380
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 30.77 (6U)
Weight (lbs): 182
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 30.77 (6U)
Weight (lbs): 182
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 30.77 (6U)
Weight (lbs): 182
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches): 17.24 x 10.30 x 30.77 (6U)
Weight (lbs): 182
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 313
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 313
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 240/120, 208/120, or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 313
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240/120 or 120
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 313
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 190
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 190
Load kVA / kW: 10kVA / 9kW
Input Voltage: 200, 208, 220, 230, or 240
Output Voltage: 208, 220, 230, or 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 190
Load kVA / kW: 10kVA / 9kW
Input Voltage: 240
Output Voltage: 240
Input Cord: Hardwired
Output Connection: Hardwired
Dimensions W x H x D (inches):
Weight (lbs): 190