10-40 kVA Three Phase, On-Line Double Conversion, Uninterruptable Power System

FirstLine PLT/FC

Frequency Converter 208 VAC, 10-60 kVA
Three phase Frequency Converter, 60Hz/50Hz for export product testing or operation of equipment rated at international frequency and voltage.

This product converts standard 208 VAC 60 Hz power to a selectable and precise 208 VAC +/- 2% 50 Hz power.  In the event of a power failure, the unit can be equipped with an internal or an optional battery cabinet to ride through a limited outage.

 


  • Hasta el 94 % de eficiencia
        o Reducción de los costes de energía y la huella de carbono
  • Compacto y Confiable
        o baterías internas 10-40 kVA permiten una huella más pequeña
        o Funcionamiento del refrigerador prolonga la vida útil de los componentes internos
  • Actuación de entrada CA
        o factor de potencia de entrada de alta de 0,99
        o Entrada de baja distorsión de la corriente de < = 1 % ( THDi ) a plena carga
        o encendido suave función walk-in que garantiza rectificador progresiva puesta en marcha
  • IGBT y procesador de señal digital (DSP )
        o Reduce el impacto de la UPS en la oferta local
        o instalación simplifica donde hay capacidad de potencia limitada
  •     entrada dual
        o de alimentación principal y de emergencia secundaria incremento de energía de reserva resiliencia de configuración individual o paralelo del sistema
  • Adaptable RSS cancelación
        o El control avanzado con tecnología de cancelación de avance AFC para baja distorsión armónica
  • Seleccione Menú Display
        o Pantalla de uso fácil es fácil de ver y de uso intuitivo
  • Paralelo hasta 4 unidades
        o proporciona redundancia para aplicaciones de misión crítica sin hardware adicional
        o Kit paralelo , comunicación a través de tarjeta paralela CANBUS
  • Funciona como un acondicionador de alimentación de precisión
        o -0 modelos pueden funcionar como un acondicionador de alimentación ampliable a un SAI en el futuro
  • Conversión de frecuencia
        o Todas las unidades se pueden configurar como un convertidor de 50/60 Hz fequency Programa de Servicio a nivel nacional
        o el personal de servicio o capacitados Fábrica maximizar la vida del equipo
        o servicios completos de puesta en marcha y mantenimiento preventivo reduce el coste de propiedad
  • Garantía completa de dos años
  • Médico
  • Centros de Datos
  • Instalaciones Industriales
  • Educación
  • Gobierno

Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries: No
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 410
Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 37
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 950
Battery Runtime @ 100% Load (Internal): 37
Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 18
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 735
Battery Runtime @ 100% Load (Internal): 18
Load kVA: 10
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 9
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 630
Battery Runtime @ 100% Load (Internal): 9
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries: No
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 410
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 21
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 950
Battery Runtime @ 100% Load (Internal): 21
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 10
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 735
Battery Runtime @ 100% Load (Internal): 10
Load kVA: 15
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 3
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 630
Battery Runtime @ 100% Load (Internal): 3
Load kVA: 20
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries: No
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 410
Load kVA: 20
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 14
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 950
Battery Runtime @ 100% Load (Internal): 14
Load kVA: 20
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 6
Dimensions (H" x W" x D"): 47.1 x 20.3 x 33
Weight (lbs.): 630
Battery Runtime @ 100% Load (Internal): 6
Load kVA: 30
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries: No
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 585
Load kVA: 30
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 8
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 1125
Battery Runtime @ 100% Load (Internal): 8
Load kVA: 40
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries: No
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 585
Load kVA: 40
Input and Output Voltage: 208/120
Internal Maintenance Bypass:
Internal Batteries:
Battery Runtime: 4
Dimensions (H" x W" x D"): 52 x 23.2 x 33
Weight (lbs.): 1185
Battery Runtime @ 100% Load (Internal): 4